Part Number Hot Search : 
2SC2899 TEA1066 0505S 10ETF10 TLE426 Z5232 CMUD4448 RATED
Product Description
Full Text Search
 

To Download TES113ZD-A3V Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  description features technical specifications ? planar magnetics ? 1500v isolation ? 45a 3/4-brick ? very-high efficiency ? open-frame packaging ? 100c baseplate operation ? synchronous rectification ? low-voltage output tes dc-dc series data sheet single-output, 150 watts page 1 of 3 rev. nov 14, 2003 tes single output dc-dc converters provide up to 150 watts of output power at up to 45a of output current in an industry-standard 3/4-brick package. the tes converters feature open-frame packaging, along with planar magnetics and a high efficiency topology, to provide maximum useable power density. the tes converters use 100% surface-mount construction and are fully-compatible with production board washing processes. voltage range 48 vdc nominal 36 - 72 vdc input output setpoint accuracy 1% line regulation v in min. - v in max., i out rated 0.2% v out load regulation i out min. - i out max., v in nom. 0.5% v out remote sense headroom 0.5 vdc minimum output current 10 % i out rated dynamic regulation, loadstep 25% i out pk deviation 4% v out settling time 500 s voltage trim range 10% current limit type latch current limit threshold range, % of i out rated 110 - 140% short circuit threshold range, % of i out rated 200% ovp trip range 115 - 140% v out nom. uvp trip range 70 - 90% v out nom. ovp/uvp type latch notes ? mtbf predictions may vary slightly from model to model. specifications typically at 25c, normal line, and full load, unless otherwise stated. soldering conditions: i/o pins, 260c, ten seconds; fully compatible with commercial wave-soldering equipment. safety: agency approvals may vary from model to model. please consult factory for specific model information. tes150ze-a 55 60 65 70 75 80 85 90 95 10 20 30 40 50 60 70 80 90 100 load % eff. (36v) eff. (48v) eff. (75v) efficiency vs. load (48v input) turn-on time 10 ms remote shutdown positive logic remote shutdown reference v in negative switching frequency 5v out / 3.3v & 2.5v out 300 khz / 200 khz isolation input - output 1500 vdc input - case 1050 vdc output - case 500 vdc temperature coefficient 0.02%/c case temperature operating range -40 to +100c storage range -40 to +125c thermal shutdown range 105 to 115c vibration, 3 axes, 5 min each 5 g, 10 - 55 hz mtbf ? (bellcore tr-nwt-000332) 1.0 x 10 6 hrs safety ul, cul, tuv weight (approx.) 3.3 oz general
model input voltage input voltage maximum input output rated output ripple & noise typical (volts) range (volts) current (amps)* voltage (volts) current (amps) pk-pk (mv) efficiency** tes113zd-a 48 36-72 4.0 2.5 45 100 80% tes150ze-a 48 36-72 5.1 3.3 45 100 83% notes: * maximum input current at minimum input voltage, maximum rated output power. ** at nominal v in , rated output. model selection mechanical drawing tes dc-dc series data sheet single-output, 150 watts page 2 of 3 rev. nov 14, 2003 
 
 
 
 


 

 
 
 
 
     




 
     
         ! "#           
  
  
 
 1-v in 2 enable 3 case 4+v in 5 cn2 (opt.) 6 cn1 (opt.) 7+v out 8+v out 9-v out 10 -v out 11 -sense 12 trim 13 +sense pin function thermal impedance note: thermal impedance data is dependent on many environmental factors. the exact thermal performance should be validated for specific application. natural convection 5.7 c/w 100 lfm 3.9 c/w 200 lfm 2.6 c/w 300 lfm 1.9 c/w 400 lfm 1.7 c/w inches: (millimeters) .xx 0.020 .x 0.5 .xxx 0.010 .xx 0.25 pin: 0.002 0.05 (dimensions as listed unless otherwise specified.) tolerances
options page 3 of 3 rev. nov 14, 2003 this page is offered as a reference. consult factory for actual availability of options. when ordering equipment options, use the following suffix information. select preferred option(s) and add the suffix to the model number. ordering option examples are located below the options table. example options: hbs050zg-ant3v = hbs050zg-a with negative logic, lucent-compatible trim, and 0.95? vertical heatsink. les015yj-3n = les015yj with optional trim and enable, negative logic. qbs066zg-at8 = qbs066zg-a with lucent-compatible trim and 0.110? pin length. nuclear and medical applications - power-one products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divi sional president of power-one, inc. technical revisions - the appearance of products, including safety agency certifications pictured on labels, may change dependin g on the date manufactured. specifications are subject to change without notice. option suffix applicable series remarks negative logic n has, hbd, hbs, hes, hls, hld, les, ttl "low" turns module on qbs, qes, qls, tes, tqd ttl "high" turns module off lucent-compatible trim t has, hbd, hbs, hes, hls, qbs, qes, qls trim 1 ias, les enable 2 iad, ias, les, sms trim and enable 3 ias, les pin length and heatsink options standard pin length is 0.180" (4.6mm) 0.110" (2.8mm) pin length 8 all leaded models 0.150" (3.8mm) pin length 9 all leaded models 0.24" (6.1mm) horizontal heatsink 1h all 1/4-bricks, 1/2-bricks, 3/4-bricks, full-bricks includes thermal pad (except hls, hld, qls, tld, and tkd packages) 0.24" (6.1mm) vertical heatsink 1v all 1/4-bricks, 1/2-bricks, 3/4-bricks, full-bricks includes thermal pad (except hls, hld, qls, tld, and tkd packages) 0.45" (11.4mm) horizontal heatsink 2h all 1/4-bricks, 1/2-bricks, 3/4-bricks, full-bricks includes thermal pad (except hls, hld, qls, tld, and tkd packages) 0.45" (11.4mm) vertical heatsink 2v all 1/4-bricks, 1/2-bricks, 3/4-bricks, full-bricks includes thermal pad (except hls, hld, qls, tld, and tkd packages) 0.95" (24.1mm) horizontal heatsink 3h all 1/4-bricks, 1/2-bricks, 3/4-bricks, full-bricks includes thermal pad (except hls, hld, qls, tld, and tkd packages) 0.95" (24.1mm) vertical heatsink 3v all 1/4-bricks, 1/2-bricks, 3/4-bricks, full-bricks includes thermal pad (except hls, hld, qls, tld, and tkd packages)


▲Up To Search▲   

 
Price & Availability of TES113ZD-A3V

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X